Welder using an on-gun fume extraction system
Free onsite audit WES to WEL

Is your fume control ready for 1 Dec?

Register for a free onsite welding fume audit from ATOM and Apex Welding Safety. We look at the controls you already have. We show you where the gaps are against the new limits. You get clear, practical next steps to be ready for 1 December. No cost. No obligation.

How it works

Get your free site audit

Tell us about your site and your ATOM rep will be in touch to lock in a date. Registering doesn't commit you to anything.

Audit places are limited. We'll confirm availability in your area before booking.

Audits delivered in partnership with
Apex Welding Safety (AWS)
What you'll walk away with

A straight answer on where your site stands

From 1 December 2026, Workplace Exposure Limits replace the old standards, and some welding fume components drop sharply. Manganese, for one, falls from 1 to 0.1 mg/m³ (inhalable). On top of that, the AS/NZS ISO 21904 series now sets the bar for fume extraction equipment. The audit puts both against what's actually on your site.

What the new limits mean for you

Which changes actually apply to the processes and materials on your site.

Whether your controls stack up

A look at your extraction, ventilation and respiratory protection as they're used day to day.

Gaps against the extraction standard

How your on-gun and LEV gear compares with the AS/NZS ISO 21904 series.

Clear, practical next steps

What to fix first, starting at the source rather than the respirator.

What's in the fume

Four fume components facing big cuts

Several common fume components get much tighter limits from 1 December 2026.

Mn

Manganese

10× lower

Consumables used to weld steels and some aluminium alloys.

Long-term exposure is linked to neurological and nervous system disorders.
Current WES1 mg/m³ (inhalable)
New WEL0.1 mg/m³ inhalable · 0.02 mg/m³ respirable
Be

Beryllium

100× lower

Found in some copper and aluminium alloys.

Can cause metal fume fever and respiratory damage, and raises lung cancer risk.
Current WES0.002 mg/m³
New WEL0.00002 mg/m³
Cd

Cadmium

10× lower

From cadmium-plated parts and brazing alloys.

Linked to respiratory irritation, breathing difficulties, kidney damage and emphysema.
Current WES0.01 mg/m³
New WEL0.001 mg/m³
CrVI

Chromium VI

No safe level

From welding stainless steel and using high chromium-alloy consumables.

Linked to an increased risk of lung cancer.
Current WES0.05 mg/m³
New WELNo numerical limit

No safe level. Eliminate or minimise exposure.

Bars show each new limit against the current standard. Check Safe Work Australia's WEL list for your site.

How it works

Four steps, no sales pitch

01

Fill out the online form

Complete the online form with your site details and roughly how many people weld there.

02

We review your request

We review every request we receive. For eligible requests, an ATOM rep will be in touch to organise a site visit.

03

Onsite walk-through

A welding fume specialist from Apex Welding Safety and an ATOM representative walk your welding areas with you.

04

Your next steps

You will be presented with findings and practical next steps for your business to meet the new welding exposure limits.

Two welders in a workshop using on-gun fume extraction
Who it's for

If you weld on site, it's worth your time

Built for workplaces where welding is a regular part of the job, from a single fab bay to a full maintenance workshop. You don't need to have your paperwork sorted first. That's partly what we're there for.

Mining and mining services
Construction
Defence
Manufacturing
HSE and site managers
Workshop supervisors
Product highlights

The right controls for your site

The right controls depend on your site, your processes and what you weld. Many sites need a mix: extraction to capture fume at the source, plus respiratory protection where exposure remains. Your audit will help you work out what's right for yours.

Nederman GoMax fume eliminator with one Translas 400A extraction gun
Engineering controls

Nederman GoMax + Translas 400A on-gun extraction kit – one welder

A portable unit that pulls fume away at the gun, before it reaches your welder's breathing zone.

  • Captures up to 98% of fume at the source
  • Complies with the AS/NZS ISO 21904 series
ATOM code 40078756View product
Plymovent self-cleaning single arm welding fume extractor
Engineering controls

Plymovent Self-Cleaning Single Arm Welding Fume Extraction System

A mobile extractor with a 3m arm you position over the weld to capture fume at the source.

  • 3m metal extraction arm, easy to move on castors
  • Self-cleaning filter, single phase and quiet to run
ATOM code 586643View product
Plymovent AirJet 4-stage air cleaner
Engineering controls

AirJet Air Cleaner – 4 Stage Plymovent

A standalone air cleaner that removes residual fume and dust from the wider workshop air.

  • Four-stage filtration with an E12 HEPA-rated filter
  • Up to 7,500 m³/h airflow for large workshops
ATOM code 40117505View product
3M Speedglas G5-01 welding helmet with Heavy-Duty Adflo PAPR
Respiratory protection

3M Speedglas G5-01TW welding helmet with Heavy-Duty Adflo PAPR

Powered air respiratory protection, with integrated eye and face protection.

  • Required minimum protection factor (RMPF) of 50
  • Up to 12 hours of battery runtime
ATOM code 40036640View product
View full product range
Get a head start

Read up before your audit

Plain-English guides from the ATOM team, so you can walk into the audit knowing what's changed.

Underground mine worker wearing powered air respiratory protection
Guide · Part 1

WES to WEL: What Australian Workplaces Need to Know Before 1 December 2026

What's changing on 1 December, which limits drop, rise or are new, and how to tell if your site is affected.

Read the article
Worker in coveralls and powered air respirator pressure-washing an industrial floor
Guide · Part 2

New Workplace Exposure Limits: A Practical Guide to Preparing Your Workplace

A step-by-step look at identifying, assessing, controlling and checking exposures before the deadline.

Read the article
Welder using on-gun fume extraction
Guide · Part 3

2026 Welding Fume Regulation Changes: What Australian Workplaces Need to Know

What the changes mean specifically for welding, from fume components like manganese to the new extraction equipment standard.

Read the article
Fair questions

Before you book

Is it actually free?

Yes. There's no cost and no obligation to buy anything afterwards.

Will this make my site compliant?

No audit can do that on its own. It shows you where your controls stand and what's worth fixing. Confirming actual exposure levels needs air monitoring by an occupational hygienist.

Who turns up?

Two people: a welding fume specialist from Apex Welding Safety and your ATOM representative, so you've got product know-how and someone who knows your account in the same room.

Do you cover my area?

ATOM has teams right around Australia, so we can get to most sites. If you're somewhere a bit out of the way, register anyway and we'll let you know either way.

What happens to my details?

We share them with Apex Welding Safety so they can arrange your audit, and handle them under ATOM's Privacy Policy.

Free onsite audit

DON'T LEAVE IT TOO LATE

The new limits start 1 December 2026. Places are limited, so get in early.

Request a Site Audit